I occasionally get a high pressure alarm

A high pressure alarm can sometimes occur due to solar gain which is where a portion of the waveguide is exposed to direct sunlight during the heat of the day. The air inside the waveguide expands as it gets hotter causing a rise in pressure. You can confirm this by...

I have a low pressure alarm what is the problem?

There are numerous possibilities for a low pressure alarm, to narrow the search consider your system as three parts: The waveguide, the dehydrator, and the interconnecting tubing. Isolating the dehydrator from the other two parts will determine if the problem is in...

Why do I keep getting the A12 dew point alarm?

The A12 dew point alarm means that the internal humidity sensor is detecting moisture in the canisters. Usually, an alarm may occur for a few seconds and reset itself before it is seen as the unit determines a need to regenerate a canister. At times with high outside...

How do I setup my ASM-1 Smart Manifold?

The setup of the ASM-1 smart manifold can be done with the following steps: Set up the IP configurations for the Netcom’s and the smart manifold (configuration page) Set up the pressure parameters on the Netcom’s and set them for large system operation Netcom...

Why is there a plug in port number 8?

Actually, there isn’t a plug in port number 8, it is a bleed. If you examine it very closely you will notice that there is a small hole in the middle of it. This is used by the Smart Manifold to bleed off pressure if it senses that it is too high and during its...